Delta DRL-48V240W1EN Lyte II Serisi Din-Rail 240W 48V 5A Power Supply
Output | |
Output Current | 5A |
Output Voltage | 48V |
Output Voltage Range | 43.2-52.8 Vdc |
Output Voltage Adjustment Range | 43.2-52.8Vdc |
Output Power | 240W |
Line Regulation | ± 0.5% @ 115Vac & 230Vac |
Load Regulation | ± 0.5% |
PARD | < 200mVpp @ 0°C to +70°C < 600mVpp @ -30°C to 0°C |
Start up Time | 30ms typ. @ 115Vac & 230Vac |
Hold up Time | 20ms typ. @ 115Vac (100% load) 20ms typ. @ 230Vac (100% load) |
Dynamic Response (Ovenshoot & Undershoot O/P Voltage) | ± 10% @ 115Vac & 230Vac input, 10-100% load (Slew Rate: 2.5A/μS, 50% duty cycle @ 5Hz & 10KHz) |
Start up with Capacitive | 3,000µF Max |
Rise Time | 30ms typ. @ 115Vac & 230Vac |
Input | |
Input Voltage | 100-240Vac |
Input Voltage Range | 90-264vVac |
Nominal Input Frequency | 47-63Hz |
Input Current | 2.5A typ. |
Efficiency at 100% load | 90.5% typ. @ 230Vac |
Max Inrush Current | 40A typ.@230Vac |
Mechanical | |
Case Chassis / Cover | Aluminum / SGCC |
Indicator | Green LED (DK OK) |
Cooling System | Convection |
Input Terminal | 3 pins (rated 300V/30A) |
Output Terminal | 4 pins (rated 300V/20A) |
Noise Sound Pressure Level (SPL) | < 25dBA |
Mounting Rail | Standard TS35 DIN Rail in accordance with EN 60715 |
Unit Weight | 0.62 kg (1.37 Ib) |
Dimensions | 123.6 x 40 x 117.2 mm 4.87” x 1.57” x 4.61” |
Environment | |
Vibration (Operating ) | IEC 60068-2-6, Sine Wave: 10Hz to 500Hz @ 19.6 m/s² (2G peak); 10 min per cycle, 60 min for X direction |
Shock Test (Operating) | IEC 60068-2-27, Half Sine Wave: 10G for duration of 11ms; 1 time in X axis |
Operating Temperature | -30°C to +70°C (-40°C Cold Start) |
Storage Temperature | -40°C to +85°C |
Power De rating | > 40°C de-rate power by 1.67 % / °C @115Vac > 50°C de-rate power by 2.5 % / °C @230Vac |
Operating Humidity | 20 to 90% RH (Non-Condensing) |
Shock Test (non operating) | IEC 60068-2-27, Half Sine Wave: 50G for duration of 11ms; 3 times per direction, 9 times in total |
Vibration (non operating) | IEC 60068-2-6, Random: 5Hz to 500Hz (2.09G); 20 min per axis for all X, Y, Z direction |
Operating Altitude | 0 to 5.000 Meters (16,400 ft.) |
Pollution Degree | 2 |
Over Voltage Categort | II (Compliance to EN 62477-1 OVC III with 2000 meters altitude) |
Protections | |
Overvoltage | <64.8V, SELV Output, Latch Mode |
Overload / Overcurrent | 105 – 150% of rated load current, Auto-recovery Continuous current limit Mode (Vo>80%) |
Over Temperature | Latch Mode |
Short Circuit | Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed) |
Protection Aganist Shock | Class I with Primary Earth connection |
Reliability | |
MTBF | > 700,000 hrs. as per Telcordia SR-332 I/P: 115Vac & 230Vac, O/P: 100% load, Ta: 25°C |
Expected Cap Life Time | 10 years (230Vac, 50% load @ 40°C) |
EMC | |
Emission | CISPR 32, EN 55032, EN 61000-6-4, AS/NZS CISPR32, EN 61204-3 Compliance to FCC Title 47, EN 61000-6-3: Class B |
Immunity | EN 55035, EN 61000-6-2 Compliance to EN 61000-6-1 |
Harmonic Current Emissions | IEC/EN 61000-3-2, Class A |
Voltage Fluctuation and Flicker | IEC/EN 61000-3-3 |
ESD Immunity | IEC 61000-4-2 |
Radiated Immunity | IEC 61000-4-3 |
EFT | IEC 61000-4-4 |
Surge | IEC 61000-4-5 |
Conducted Immunity | IEC 61000-4-6 |
Magnetic Field | IEC 61000-4-8 |
Voltage Dips | IEC 61000-4-11 |