Fluke Networks OptiFiber Pro OTDR Family
- Multiple wavelengths (850, 1300, 1310,1490, 1550 and 1625 nm) support LAN, datacenters, PON, FTTx and outside plant applications.
- Automated setup senses fiber characteristics and sets measurement parameters
- Manual Expert mode allows simple adjustments to automated settings for detailed testing.
- EventMap automatically identifies events including connectors, splices, bends, and splitters
- Gesture-based interface allows fast, in-depth trace analysis
- SmartLoop™ OTDR technology tests two fibers in a single test eliminating the need to travel to the far end of the connection to perform tests.
- Instantaneous on-board bi-directional averaging results included as standard
- Integrates with LinkWare™ Live to manage jobs and testers from any smart device.
- Future-ready VersivTM design supports copper certification to Category 8, fiber loss and inspection.
Designed for Enterprise, Datacenter, Outside Plant and PON Fiber
As fiber networks evolve, the need to test in more locations has increased. OTDRs are now needed for:
FTTx
Enterprise
OSP
PON
POLAN
Many OTDRs designed for fiber troubleshooting are designed for carrier and contain cumbersome and complicated features.
The OptiFiber Pro OTDR family is the first class of OTDRs that is built with features and usability for both the enterprise
network engineers, and cable installers working in both enterprise and OSP environments.
OFP2-100-M INT OptiFiber Pro Multimode Wi-Fi enabled OTDR: Versiv2 Main + OTDR module
OFP2-100-S INT OptiFiber Pro Singlemode Wi-Fi enabled OTDR: : Versiv2 Main + OTDR module
OFP2-100-Q INT OptiFiber Pro Quad (Multimode and Singlemode) Wi-Fi enabled OTDR: Versiv2 Main + OTDR module
Key OptiFiber Pro OTDR specifications | |||
Multimode module | Singlemode Module | Quad module | |
Wavelength | 850 nm +/- 10 nm 1300nm+35/15nm |
1310 nm +/- 25 nm 1550nm+/- 30nm |
850 nm +/- 10 nm 1300nm+35/- 15nm 1310nm+/- 25nm 1550nm+/- 30nm |
Compatible fiber types | 50/125 µm 62.5/125µm |
Singlemode | 50/125 µm 62.5/125 µm Singlemode |
Event dead zone 1 | 850 nm: 0.5 m typical 1300nm: 0.7m typical |
1310 nm: 0.6 m typical 1550nm: 0.6m typical |
850 nm: 0.5 m typical 1300nm :0.7m typical 1310nm: 0.6m typical 1550nm: 0.6m typical |
Attenuation dead zone 2 | 850 nm: 2.5 m typical 1300nm: 4.5m typical |
1310 nm: 3.6 m typical 1550nm: 3.7 typical |
850 nm: 2.5 m typical 1300nm: 4.5m typical 1310nm: 3.6m typical 1550nm: 3.7m typical |
Dynamic range 3, 5, 6 | 850 nm: 28 dB typical 1300nm: 30dB typical |
1310 nm: 32 dB typical 1550nm: 30dB typical |
850 nm: 28 dB typical 1300nm: 30dB typical 1310nm: 32dB typical 1550nm: 30dB typical |
Max distance range setting | 40 km | 130 km | MM: 40 km SM: 130km |
Distance measurement range 4, 5, 7, 8, 9, 10 | 850 nm: 9 km 1300nm: 35km |
1310 nm: 80 km 1550nm: 130km |
850 nm: 9 km 1300nm:35km 1310nm:80km 1550nm:130km |
Reflectance range 4, 5 | 850 nm: -14 dB to -57 dB (typical) 1300nm: -14dB to -62dB (typical) |
1310 nm: -14 dB to -65 dB (typical) 1550nm: -14dB to -65dB (typical) |
850 nm: -14 dB to -57 dB (typical) 1300nm: -14dB to -62 dB (typical) 1310nm: -14dB to -65dB (typical) 1550nm: -14dB to -65dB (typical) |
Sample resolution | 3 cm to 400 cm | 3 cm to 400 cm | 3 cm to 400 cm |
Pulse widths (nominal) | 850 nm: 3, 5, 20, 40, 200 ns 1300nm: 3,5,20,40,200,1000ns |
1310/1550 nm: 3, 10, 30, 100, 300, 1000, 3000, 10000, 20000 ns | 850 nm: 3, 5, 20, 40, 200 ns 1300nm : 3,5,20,40,200,1000ns 1310/1550nm:3,10,30,100,300,1000, 3000,10000,20000ns |
Test time (per wavelength) | Auto setting: 5 sec (typical) Quick test setting: 2sec (typical) Best resolution setting:2 to 180 sec FaultMap setting: 2sec (typical),180sec (max) DataCenter OTDR setting:1 sec (typical at 850nm), 7sec(max) Manual setting: 3,5,10,20,40,60,90,120,180sec |
Auto setting: 10 sec (typical) Quick test setting: 5sec (typical) Best resolution setting:5 to 180 sec FaultMap setting: 10sec (typical),180sec (max) DataCenter OTDR setting:20 sec (typical),40 sec(max) 7sec(max) Manual setting: 3,5,10,20,40,60,90,120,180sec |
Auto setting: MM – 5 sec (typical) SM – 10 sec (typical) Auto setting: MM – 5 sec (typical) SM – 10 sec (typical) Quick test setting: MM – 2 sec (typical) SM – 5 sec (typical) Best resolution setting: MM – 2 to 180 sec M SM – 5 to 180 sec FaultMap setting: MM – 2 sec (typical), MM – 180 sec (max) SM – 10 sec (typical), SM – 180 sec (max) DataCenter OTDR setting: MM – 1 sec (typical at 850 nm) MM – 7 sec (max) SM – 20 sec (typical) SM – 40 sec (max) Manual setting: -3, 5, 10, 20, 40, 60, 90, 120, 180 sec SM – 3, 5, 10, 20, 40, 60, 90, 120, 180 sec |
Key OptiFiber Pro HDR Specification | |||
Wavelengths | 1310 nm +/- 25 nm 1550nm +/- 20nm |
1310 nm +/- 25 nm 1490 nm +/- 20nm 1550nm +/- 20nm |
1310 nm +/- 25 nm 1550 nm +/- 20nm 1625nm +/- 20nm |
Compatible fiber types | Singlemode | Singlemode | Singlemode |
OTDR Port Connector | Cleanable APC ferrule with removable SC adapter | Cleanable APC ferrule with removable SC adapter | Cleanable APC ferrule with removable SC adapter |
Event dead zone 1 | 0.7 m (typical) | 0.7 m (typical) | 0.7 m (typical) |
Attenuation dead zone2 | 4m (typical) | 4m (typical) | 4m (typical) |
PON dead zone3 | 30 m (typical) | 30 m (typical) | 30 m (typical) |
Max distance range setting | 260 km | 260 km | 260 km |
Dynamic range 4, 5 | 1310 nm: 42 dB (typical 1550nm: 41dB (typical) |
1310 nm: 42 dB (typical) 1490nm :41dB (typical) 1550nm :41dB (typical) |
1310 nm: 42 dB (typical) 1550nm :41dB (typical) 1625nm :40dB (typical) |
Reflectance range4 | -14 to -70 dB (typical) | -14 to -70 dB (typical) | -14 to -70 dB (typical) |
Sampling resolution | 3 cm to 2 m | 3 cm to 2 m | 3 cm to 2 m |
Sampling points | 3 cm to 2 m | 3 cm to 2 m | 3 cm to 2 m |
Sampling points | Up to 129000 | Up to 129000 | Up to 129000 |
Pulse widths (nominal) | 5, 10, 30, 50, 100, 300, 500, 1000, 3000, 5000, 10000, 20000 ns | 5, 10, 30, 50, 100, 300, 500, 1000, 3000, 5000, 10000, 20000 ns | 5, 10, 30, 50, 100, 300, 500, 1000, 3000, 5000, 10000, 20000 ns |
Distance uncertainty | +/-(1 + 0.0005*distance + 0.5*resolution) | +/-(1 + 0.0005*distance + 0.5*resolution) | +/-(1 + 0.0005*distance + 0.5*resolution) |
Linearity | ± 0.03 dB/dB | ± 0.03 dB/dB | ± 0.03 dB/dB |
Reflectance uncertainty | ±2 dB | ±2 dB | ±2 dB |
Test Time (per wavelength) | Auto setting: 5 seconds/wavelength (typical) Auto PON setting: 10 seconds/wavelength (typical) Manual setting: 3, 5, 10, 20, 40, 60, 90, 120, 180 seconds/wavelength Manual PON setting: 3, 5, 10, 20, 40, 60, 90, 120, 180 seconds/wavelength Quick test setting: 3 seconds/wavelength (typical) Best resolution setting: 5 to 180 seconds/wavelength |
Auto setting: 5 seconds/wavelength (typical) Auto PON setting: 10 seconds/wavelength (typical) Manual setting: 3, 5, 10, 20, 40, 60, 90, 120, 180 seconds/wavelength Manual PON setting: 3, 5, 10, 20, 40, 60, 90, 120, 180 seconds/wavelength Quick test setting: 3 seconds/wavelength (typical) Best resolution setting: 5 to 180 seconds/wavelength |
Auto setting: 5 seconds/wavelength (typical) Auto PON setting: 10 seconds/wavelength (typical) Manual setting: 3, 5, 10, 20, 40, 60, 90, 120, 180 seconds/wavelength Manual PON setting: 3, 5, 10, 20, 40, 60, 90, 120, 180 seconds/wavelength Quick test setting: 3 seconds/wavelength (typical) Best resolution setting: 5 to 180 seconds/wavelength |
Laser Classification | Class 1 CDRH Complies to EN 60825-2, 3rd Edition | Class 1 CDRH Complies to EN 60825-2, 3rd Edition | Class 1 CDRH Complies to EN 60825-2, 3rd Edition |
Calibration Period | 1 year | 1 year | 1 year |